Jiangsu Plaza Premium Electric Instrument Co.,Ltd.(HY)
Thermocouple And Extension Cable - Single Pair

Silicone Rubber Thermocouple Cable

Product description

Thermocouple extension wire is used to extend the thermode, that is, the cold junction of the movable thermocouple connect with indicating instrument to make up temperature measurement system.

 Extension wire falls into two kinds; one is extension type and the other is compensation type. The wire same with the two thermocouple wires of the Graduation Mark, is know as the extension type. The wire same with, formed by cooper—-cupronickel materials with different proportion, is called compensation type.

 The two kinds of extension wire, both have good property of resistance to acid, alkali, abrasion and fire. It’s temperature range used commonly is -25-400C. In addition, it can be used for a long time by immersing into the oil. The extension wire complies with GB/T4989-94-2016 standard.

 The extension wire types can be divided into WC, BC,SC, RC, NX, KC, KX, EX, JX and TX in accordance with the product type. 

Silicone rubber insulated thermocouple extension wire– Single pair

. Continuous use up to 180°C

. Short term use up to 250°C

. Good electrical and mechanical properties
. Good flame retardance and moisture resistance

Silicone rubber Physical Properties

CharacteristicsInsulationJacket
Abrasion ResistanceExcellentExcellent
FlexibilityExcellentExcellent
Moisture ResistanceGoodGood
WeatherabilityExcellentExcellent
Service Temperature180°C continuous250°C single180°C continuous250°C single
Flame TestSelf-extinguishingSelf-extinguishing

Color Code & Initial Calibration Tolerance for Thermocouple Extension Wire:

Thermocouple extension typeThermocouple extension typeANSI Color CodeANSI Color CodeInitial Calibration TolerancesInitial Calibration TolerancesInitial Calibration Tolerances
Wire AlloysCalibrationConductor (+/-)JacketTemperature RangeStandard
Limits
Special
Limits
Iron (+) vs.  Constantan(-)JXWhite/RedBlack0°C to +200°C± 2.2°C± 1.1°C
Chromel (+) vs.  Alumel (-)KXYellow/RedYellow0°C to +200°C± 2.2°C± 1.1°C
Copper(+) vs. Constantan(-)TXBlue/RedBlue-60°C to +100°C± 1.1°C± 0.5°C
Chromel(+) vs. Constantan(-)EXPurple/RedPurple0°C to +200°C± 1.7°C± 1.1°C
Nirosil (+) vs. Nisil (-)NXOrange/RedOrange0°C to +200°C± 2.2°C± 1.1°C
Copper (+) vs. Alloy 11 (-)RX/SXBlack/RedGreen0°C to +200°C± 5°C
Copper S (+) vs. -Copper E (-)BXGray/RedGray0°C to +200°C± 3.7°C

Nominal Insulation Thickness:

Wire Size (AWG)Conductor Insulation Thickness (mm)Jacket Insulation Thickness (mm)Outer Diameter (mm)
200.400.805±0.20
20 7/280.400.805±0.20
240.400.804.2±0.20
24 7/320.400.804.2±0.20
260.350.804.0±0.20
280.350.804.0±0.20
300.350.803.6±0.20

Applications
* Metallurgy
* Chemical industry, petroleum
* Power generation
* Defense and scientific research
* Cables for connection between thermocouples and temperature display instrument.

Features

1) Continuous use up to 180℃

2) Short term use up to 250℃

3) Excellent heat, chemical, abrasion and moisture resistance

4) Provides accurate temperature measure with high temperature stability

5) Calibration test report is available

Images

Product Specifications

Item Specification - -
Calibration Type JX Type KX Type TX Type EX Type NX Type RX/SX Type BX
+ Iron - Constantan + Chromel - Alumel + Copper - Constantan + Chromel - Constantan + Nirosil - Nisil + Copper - Alloy 11 + Copper-S - Copper-E
- Alumel + Copper
Wire size 20, 24, 26, 28, 30AWG
Wire type Solid or Stranded
Construction Parallel conductors
Number of pair Single
Insulation Silicone rubber
Jacket Silicone rubber
Tolerance Standard limits of error or special limits of error
Max. Operating temperature 180°C
Color code ANSI, IEC, JIS, DIN, BS, NFC
Packing Roll or spool (As required)
Chromel(+) vs. Constantan(-) EX Purple/Red Purple 0°C to +200°C ± 1.7°C ± 1.1°C
Nirosil (+) vs. Nisil (-) NX Orange/Red Orange 0°C to +200°C ± 2.2°C ± 1.1°C
Copper (+) vs. Alloy 11 (-) RX/SX Black/Red Green 0°C to +200°C ± 5°C -

Inquiry Now