Product description

Water lines and process pipe systems can become a real problem when temperatures drop below freezing. It’s only when the thaw comes that you realize the damage a split or cracked water pipe can cause.Water Pipe Heating Cable provides a reliable heating solution to the problem of frozen pipe,it can prevent frost damages and keep liquids floating at all outside temperatures.

It incorporates a splice, insulated cover and a metal clad sheath to ensure product longevity.

The cable is available in a variety of length ranging, making it ideal for any residential, commercial or heavy industrial application.

The water pipe heating cable has the energy-saving temperature controller. When the temperature reaches the critical range, it will start the protection pipe automatically.

The installation of the water pipe heating cable is convenient and you can install it by yourself. It is appropriate for the plastic and metal pipe.

Features:

1. The heating cable can prevent the freeze of the pipe and enable water to flow normally below 0°C

2. Maintenance of the required temperature in pipes

3. The heating cable uses thermostat to save energy. Thermostat -ON:6±3°C–OFF:13±3°C

4. Easy installation

5. Reliable operation

6. Residential, Commercial or industrial applications

7. Be suitable for use on plastic and metal water popes.

8. This system can be installed with confidence and with the assurance that it will operate for years.

Installation:

First unwind the heating cable. The cable must never be connected to the power line when it is wound up.

If the cable is too inflexible because of low temperatures, unwind it and put it for some minutes into the plug.

Afterwards you can pass the cable,the area around the pipe where you want to connect it with the cable must be accessibly and non-attached.

the heating cable can not be passed behind walls

put the thermostat with the round black contact area tightly on the coolest point of the pipe and fix it with insulating tape.

finally put the whole cable on the pipe and fasten it every 30~60cm with insulating tape.

Attention: the cable must be fastening straight on the pipe

now you can check if your cable works.

afterwards insulate the water pipe and the heating cable with mineral rock wool or foam.

Attention: never use more than 13mm of this material to insulate.

in general the heating cable must be protected against mechanical damage or biting.

the heating cable can not be put into liquids.

finally plug the cable into a 230V main plug.

Product Specifications

Installation Steps
1 Unwind the heating cable and check is there any damage on the cable body. Once receive the damaged cable, please contact us to change a new one. If low temperature cause the cable too inflexible, unwind it and plug in for several minutes.
2 Clean the pipe surface, make sure it is smooth and without any sharp protuberance.
3 Put down heating cable along the pipe, and make the thermostat's sensing part (a black round block) attach to the pipe surface tightly at the coolest point.
4 Fix the thermostat's sensing part by insulating tape firstly, then fasten the remaining cable at every 30~60cm interval. Make sure all fixing is stable.
5 (Optional) You can decide whether install the insulating material (mineral rock wool or foam) by referring to following table. (The thickness of insulating material should be s13mm)
Pipe Caliber - 15mm 22mm 28mm 35mm 42mm 48mm 60mm 76mm
Without pipe insulation - -20 -13 -10 -7 -5 -4 -3 -2
With 13mm pipe insulation - -45 -45 -40 -40 -35 -30 -25 -20